Medical Equipments

CLINICAL LAB DEVICES

  • EUROTAJ TG-9602 Microplate Reader

Specifications

  • Measurement System  :8-Channel optical system
  • Measurement Range : 0.001~3.000Abs
  • Photometric Accuracy :±0.01Abs  (0.001~1.500Abs
  • Repeatability :  <±0.5% (0.001~1.500Abs)
  • Stability : < 0.005Abs
  • Linearity :< ±1% (0.001~1.500Abs)
  • Filters :Standard:4 filters (405,450,492,630nm), Totally 7 filters can be installed

  • EUROTAJ TG-9602A Microplate Reader

Specifications

  • Measurement System :2-Channel optical system
  • Measurement Range :  0.001—3.500Abs
  • Photometric Accuracy :  ±1% or ±0.001Abs
  • Repeatability :  < ±0.5%
  • Stability : < 0.005Abs
  • Linearity : < ±1%

  • EUROTAJ TG-2018 Biochemistry Analyzer

Specifications

  • Wavelength Range : 340nm~750nm
  • Measurement Range : 0.001~3.000Abs
  • Precision : ±0.001Abs
  • Repeatability : ≤0.005Abs
  • Linearity : ≤±1%
  • Cross-contamination : ≤1%
  • Temperature Accuracy : ±0.1°C
  • Test Temperature : 25°C,30°C, 37°C
  • Test Method : end-point, kinetic, two-point , standard
                         curve and simple/double wavelength exam
  • Colorimetric Pool : Titanium alloy
  • Reagent : 400μl~800μl Match all kinds of reagent   (WITH INTERNAL PRINTER)
  • Sample volume : 20~50μl
  • Display : Photometric absorbance, density, active unit, and normal parameters

  • EUROTAJ TG-2018G Biochemistry Analyzer

Specifications

  • Wavelength Range: 340nm~750nm
  • Measurement Range: 0.000~3.000Abs
  • Repeatability: ≤0.005
  • Linearity: ≤1.0%
  • Temperature Accuracy: ±0.2°C
  • Colorimetric Pool: Titanium alloy
     Test Method: Absorbency, End-poit, Kinetic,Two-point, 
                         Standard Curve, Control Tube, Factor
  • 7.5" colorful touch screen

  • EUROTAJ TG-9620 Computerized Microplate Washer

Specifications

  • Washing Head :  8 or 12 channels
  • Applicable Microplate :  96 or 48  wells microplate
  • Washing Times Option :  1~9  presettable
  • Washing Rows Option :  1~12  presettable
  • Soak Time :  1~3600s
  • Residual Volume :  <3μl/well


  • EUROTAJ TG-1688 Urine Chemistry Analyzer

Specifications

  • Test items : GLU,BIL,KET,SG,BLO,PRO,URO,NIT and LEU
  • Working wavelength : 557nm, 610nm and 660nm
  • Test speed of single step running mode : 60/h
  • Test speed of continuous running mode : 210/h
  • Data storage : no more than 100 samples
  • Printer : internal high-speed thermal printer
  • User Information : year, month, day, week, time, sample number and sample code


  • EUROTAJ TG-2048B Two-channel Blood Coagulation Analyzer

Specifications

  • Number of Channels : 2,37°C±0.2°C
  • Reagent Storage : 4
  • Sample Preparation Positions : 6, 3 with timer
  • Reagent Volume : 100μl
  • Stray : ≤1%
  • Interchannel Error : ≤3%
  • Linearity Error : ≤1%


  • EUROTAJ TG1000B Electrolyte Analyzer

Specifications

  • It can measure the concentrations of K+, Na+ , Cl- and Ca++ and
    pH values
  • Applies ISE (Ion Selection Electrode), which gives the instrument the advantages of minimum maintenance, easy assembly and disassembly, as well as stable and reliable measurements
  • Working Modes
    • Normal mode: automatic calibration; this mode adapts to large and middle scale hospital with large sample volume; sleep functions which can save reagent
    • Saving mode: 24 hours reagents consumption is only 7ml when it does not measure. This mode. adapts to hospital with small sample volume.
  • Each test channel can be closed separately, So it is convenient to do emergency measurement.
  • 110mm×60mm LCD display, automatic screensaver, friendly interface, easy to operate
  • Mini thermal printer can print repeatedly at any moment. It is convenient to feed paper. And the print is very clear.
  • Revising datas automatically to ensure the accuracy of data.
  • It can save1500 test results, data will not be lost even if the power is cut off. Users can inquire or print at any moment.
  • The instrument is equipped with a RS232 serial port, which can be connected to computer. It may collect, manage and print measure result by relevant software.
  • It has electrode-checking function. Users can do corresponding maintenance according to checking result
  • Exempt of routine maintenance, this greatly lighten the burden of operators; In-side software self-checking can suggest users eliminate the malfunction in time.
  • Advanced and reliable fluid position examination technology can save reagent
  • Adopt built-in operating system leads to a reliable performance.
  • Users can modify each setting to meet different requirements
  • The quality-control inspecting function can track the accuracy of the instrument.



Test Object Linearity Repeatability (Cv)   Stability    Accuracy
K+ ±0.3mmol/L ≤1.0 %  ±0.2mmol/L/h     ±0.3mmol/L
Na+ ±3.0mmol/L        ≤1.0 %        ±0.2mmol/L/h    ±3.0mmol/L
Cl- ±3.0mmol/L       ≤1.0 %        ±2.0mmol/L/h   ±3.0mmol/L
Ca++ ±0.2mmol/L      ≤2.0 %      ±0.2mmol/L/h  ±0.2mmol/L
pH -- ≤1.0 %    ±0.02/h --

BLOOD ANALYZER |

  • EUROTAJ TG6000 Auto Hematology Analyzer

Specifications

  • ITest Items
    WBC, LY#, MO#, GR#, LY%, MO%, GR%, HGB, RBC, HCT, MCV, MCH, MCHC, RDW—CV, RDW—SD, PLT, PCT, MPV, PDW, WBC Histogram, RBC Histogram, PLT Histogram
    Background Count
  • WBC: ≤0.3×109/L   RBC: ≤0.03×1012/L   HGB: ≤1g/L   PLT: ≤10×109/L
  • Linearity
    Test Item        Test Range            Allow Difference of Linearity    
    WBC        0~6.0×109/L            ±0.3×109/L
                        6.0~99.9×109/L            ±5%
    RBC         0~0.99×1012/L              ±0.05×1012/ L   
                    1.0~9.99×1012/L            ±5%       
    HGB                    0~99 g/L                ±2g/L
                    100~300 g/L            ±2%
    PLT            0~99×109/L            ±10×109/L
                    100~999×109/L            ±10%
                      
  • Repeatability
    Test Item        CV (%)            Teat Range
    WBC        ≤2.0            7.0~15.0×109/L
    RBC            ≤0.5            3.5~6.0×1012/L
    HGB            ≤1.5            110~180g/L
    PLT            ≤4.0            150~500×109/L
    MCV            ≤0.5            80~110fL
           
  • Sample Volume
    Twig blood: 20μl
  • Dilution Ratio
    WBC/HGB: 1:500   RBC/PLT: 1:50000
  • Interfaces
    RS232 joint, USB, PS2, Parallel port
  • Test Speed
    60 samples/hours
    Continuous Work Time
    >8h


  • EUROTAJ TG9030B Semi-automatic Hematology Analyzer (18 Parameters)

Specifications

  • Test Items : 18 parameters: RBC, HGB, WBC, LY#, MO#,GR#, LY%, MO%, GR%,       HCT, MCV, MCH, MCHC, RDW, PLT, MPV, PCT, PDW
  • Linearity Range : RBC: 1.00~9.99×1012/L HGB: 20g/L~200g/L
  • WBC: 0.50~99.0×109/L , PLT: 50~999×109/L
  • Precision (CV) :  RBC: ≤2.5%
           HGB: ≤1.5%
           WBC: ≤3.5%
           LY%:≤6%
           MO%:≤12%
           GR%:≤6%
           MCV:≤2%
           PLT:≤5%
           MPV:≤3%
  • Dilution Ratio :  WBC / HGB      1:500,            RBC / PLT         1:50000
  • Sample volume :  Periphery/whole blood: 20μl
  • Reagents 10kgs 1. HB Non-cyanogen Hemolysin 2×15ml
          2. HB Diluent    4L
          3. HB Washing Solution    4L



  • EUROTAJ TG9030C Semi-automatic Hematology Analyzer(14 Parameters)

Specifications

  • Testing Items : RBC, HGB, HCT, MCV, MCH, MCHC, RDW,
                            WBC, LY#,  MO#,GR#, LY%, MO%, GR%,
                            White Blood Cell Histogram, Red Blood Cell Histogram
  • Linearity Range : RBC: 1.00~9.99×1012/L
                             HGB: 20g/L~200g/L , WBC: 0.50~99.0×109/L
  • Precision (CV) :   RBC: ≤2.5%, MCV: ≤2.0%, HGB: ≤1.5%, WBC: ≤3.5%
  • Principle: Blood corpuscle count-impedance, HGB--- colorimetric method with 540nm wavelength
  • Display  : LCD directly displays the working status, testing items, results and histogram
  • Sample Volume :  Periphery blood 20μl
  • Dilution Ratio :   WBC/HGB  1:500, RBC 1:50000
  • Printer :  Built-in stylus printer Print the testing parameters directly
  • Reagents 10kgs     1. HB Non-cyanogen Hemolysin 2×15ml
                                2. HB Diluent    4L
                                3. HB Washing Solution    4L


  • EUROTAJ TG-2048B Two-channel Blood Coagulation Analyzer

Specifications

  • Number of Channels : 2,37°C±0.2°C
  • Reagent Storage : 4
  • Sample Preparation Positions : 6, 3 with timer
  • Reagent Volume : 100μl
  • Stray : ≤1%
  • Interchannel Error : ≤3%
  • Linearity Error : ≤1%


  • EUROTAJ TG5000 Hematology Analyzer
Test Items WBC, LY#, MO#, GR#, LY%, MO%, GR%, HGB, RBC, HCT, MCV, MCH, MCHC, RDW—CV, RDW—SD, PLT, PCT, MPV, PDW, WBC Histogram, RBC Histogram, PLT Histogram
Performance Index
Test Item Linearity Range Precision
WBC(×109/L) 0.0-99.9 CV≤2% (4.0-10.0×109/L)
RBC (×1012/L) 0.00-9.99 CV≤1.5% (2-6.0×1012/L)
HGB (g/L) 20-200 SD≤3g/L (30-100)g/L CV≤1.5% (101-200)g/L
MCV (fL) 40.0-150 CV≤0.5% (80.0-100fL)
PLT (×109/L) 0.0-999 CV≤4.0% (100-500×109/L)
Repeatability Test Item CV (%) Test Range
WBC ≤2 4.0~10.0×109/L
RBC ≤1.5 3.5~6.0×1012/L
HGB SD≤3g/L
CV≤1.5%
(101-200)g/L
30~100g/L 101~200g/L
PLT ≤4 100~300×109/L
MCV ≤0.5 80~110fL
Sample Volume Twig blood: 20μl
Dilution Ratio WBC/HGB: 1:500RBC/PLT: 1:50000
Interfaces RS232 joint
Continuous Work Time >8h

  • EUROTAJ TG-1 Hemoglobin Meter(Vertical/Horizontal)

Specifications

  • Test Item :  Hemoglobin(HGB)
  • Test Method  :  High ferricyanide
  • Wavelength  :  540nm
  • Displayed Number :  Three-digit number
  • Measurement Range :  0~200g/L
  • Dilution Ratio :  1:251 1:501
  • Sample Volume :  2mL±10%
  • Test Time :  ≤8s
  • Linearity Error  :  <100g/L±3g/L , <100-200g/L±3%
  • Coefficient of Variation :  ≤2%
  • Power Supply  :  AC220V±10%;50Hz±2%
  • Input Power :  10W
  • Net Weight  :  2.5kg
  • Sustained Operation :  >8 hour
  • Stability :  3g/L 0.5h


X-RAY SERIES

  • EUROTAJ TG160 High Frequency X-ray Radiograph System (200mA)

Specifications

  • Power Output: 15KW
  • Inverter Frequency : 40kHz
  • X-Ray Tube :  XD56-5  17/130
                         Small focus: 0.3     Large focus: 0.6
                         Thermal capacity: 212kJ (300 KHU)
  • The speed of the rotary anode: 3000rpm
  • Tube Voltage: 40~125kV
  • Tube Current :200mA
    mAs: 1~360mAs
  • Bucky grid : Grid density 103L/INCH; Grid ratio:10:1
                      Focus distance:150cm Stationary
                      18"×18"(import)
  • Power supply : 220V 50Hz, Capacity: ≥16kW
  • Operation method: graphic remote-control LCD touch screen
                                and wireless remote-control exposure
                                (Optional: control box of graphic remote-control
                                   LCD touch screen)


  • EUROTAJ TG102 Mobile X-ray Equipment

Specifications

  • Power Output :   2.96KW
  • X-Ray Tube   :   Fixed anode
  • Commute Method  :   Full wave commutation
  • Tube Voltage :   40~90KV
  • Tube Current:   50~90KV  15mA 
                          50~90KV  30mA 
                          40~80KV  50mA
  •  Exposure Time  :  50~90KV  15mA 0.1~6.3s 
                             50~90KV  30mA   0.1~6.3s 
                             40~80KV  50mA  0.1~1.5s
  • Power Supply  :   110V±10%  60Hz 
                            inner-resistance≤0.1Ω 4KW
  • Operation Method  :   Wire /Wireless control
  • Packing Details      :   1240mm×750mm×1460mm   
                                   N.W.150kgs  G.W.210kgs



  • EUROTAJ TG101A High Frequency Mobile X-ray Equipment (63mA)

Specifications

  • Power Output  :   3.5KW
  • Frequency  :   40KHz
  • X-Ray Tube   :   Fixed anode
  • focus :   1.5mm
  • Tube Voltage :   40~110KV (interval 1KV)
  •  Tube Current :   40~49KV     63mA 1~125 mAs
                            50~59KV     56mA 1~110 mAs
                            60~69KV     45mA 1~90 mAs
                            70~79KV     40mA 1~80 mAs
                            80~89KV     36mA 1~71 mAs
                            90~99KV     32mA 1~63 mAs
                            100~110KV    20mA 1~40 mAs
  • mAs       :   1.0~125 mAs (45 steps)
  • Power Supply :   220V±10℅ 50Hz, inner-resistance≤1.0Ω
  • Operation Method :  Wire/Wireless control
  • Packing Details    :  1240mm×900mm×1460mm   
                                 N.W. 150kgs      G.W.210kgs



  • EUROTAJ TG101B High Frequency Mobile X-ray Equipment(63mA)

Specifications

  • PLX101A + Battery


  • EUROTAJ TG101C High Frequency Mobile X-ray Equipment (100mA)

Specifications

  • Power Output: 5.0KW
  • Frequency: 40KHz
  • X-ray Tube: Fixed anode
                      Focus  1.5mm
  • Tube Voltage:  40~110KV (interval 1KV)
  • Tube Current: 40~49KV        100mA    1~180 mAs
                         50~59KV        77mA      1~140 mAs
                         60~69KV        64mA      1~125 mAs
                         70~79KV        55mA      1~110 mAs
                         80~89KV        49mA      1~100 mAs
                         90~99KV        44mA      1~90 mAs
                         100~110KV   32mA      1~80 mAs
  •  mAs:   1.0~125 mAs (43 steps)
  • Power Supply:220V±10%  50Hz , inner-resistance≤1.0Ω
  • Operation Method:   Wire/Wireless control


  • EUROTAJ TG112 High Frequency Mobile X-ray C-arm System

Specifications

Fluoroscopic Capacity

  • Max rated capacity    : Tube Current 4mA, Tube Voltage 110kV
  • Automatic Fluoroscopy     : Tube Voltage:40kV~110kV adjust automatically
  • Tube Current         : 0.3mA~4mA set manually
  • Manual Fluoroscopy   : Continuous Tube Voltage:40kV~110kV
  •  Continuous Tube Current : 0.3mA~4mA
  • Pulse Fluoroscopy : Continuous Tube Voltage 40kV~110kV 
                               Continuous Tube Current 4.1mA~8mA

Photography Capacity

  • Max rated capacity   : 3.5 KW
  • Tube Voltage and Current Combination : 40kV~49kV   1 ~125 mAs
                            50kV~59kV   1 ~110 mAs, 60kV~69kV   1 ~90  mAs
                            70kV~79kV   1 ~80  mAs, 80kV~89kV   1 ~71  mAs
                            90kV~99kV   1 ~63  mAs,100kV~110kV 1 ~40  mAs

X-ray Tube

  • X-ray Tube Special for High Frequency Fixed anode X-ray tube with 2 foci: Large focus: 1.5mm, small focus: 0.6mmInverter Frequency: 40KHzThermal capacity: 30KJ (40HU)

VideoSystem

  • Image Intensifier : Image Intensifier made by TOSHIBA (9″~6″~4.5″)
  • CCD Vidicon: Import CCD Vidicon with ultra-low luminosity
  • Monitor : Horizontal 1000 lines and vertical 800 lines, Bandwidth : 12.5MHz, Image/sec : 25
  • CCU(central control)  : Recursive Filter: K=8, 7 images storage, image upright, image overturn,positive & negative image;LIH(last image freeze, and OSD(monitor display

Structure

  • Direction wheel: ±90°revolution,can change the moving direction of the unit
  • Ascending & Descending Range of Pillar : ≥400mm
  • C-arm: Forward and Backward Movement: 200mm, Revolution around Horizontal Axis:  ±180°, Revolution around Vertical Axis :  ±15, Slip on orbit: 120°(+90°~ -30°)
                                                                       ©Copyright alareejgroup